Grid Power PSF75 Waterproof Connectors
Lock design
Connector provides primary self-locking and secondary enhanced self-locking
Wire to wire and Wire to panel choice
Wire to wire, wire to panel design
Touch safe interface
To minimaze potential contact with life circuit
Flat wipping contact technology
Flat wipping contact technology, low cost design and high efficient
IP67 Rating water proof
IP67 water proof design, and provide connection and disconnection water proof design for panel side. More safety for power equirement IP rating application
HOW TO DEFINE CONNECTOR HOUSINGS
Housing Dimensions (mm)
Housing Dimensions (mm)
Housing Dimensions (mm)
Recommended panel coutout (mm)
Power contacts
Signal contacts
Housing spare parts and dust caps
Housing spare parts and dust caps
HOUSINGS SPARE PARTS AND DUST CAPS
PSF75 CONNECTOR ASSEMBLY
PSF75 2 Power and 4 Power Contacts
- Power cables must be inserted thru Back Cover (4-3) and “Cable Rubber Ring” (3-2)
- Strip cables and wires and crimp contacts then insert them into housing, according position numbers molded
on housing. Check that contacts be locked by springs - Push“Cable Rubber Ring” (3-2) into housing and lock Back Cover (4-3)
PSF75 2 Power + 8 Signal Contacts
- Power cables and signal wires must be inserted thru Back Cover (5-4),“Cable Rubber Ring” (4-3) and
Signal Rubber Ring” (3-2) - Strip cables and wires and crimp contact
- Insert Power Contacts according positive and negative polarity indicated on housings
- Insert male Signal Contacts into“Holder” (6) positioned into female housing and
female Signal Contacts into“Holder” (6) positioned into male housing - Push“Cable Rubber Ring” (4-3) and Signal Rubber Ring” (3-2) into housing and lock Back Cover (5-4)
PSF75 CONNECTOR DISASSEMBLY
PSF75 2 Power and 4 Power Contacts
- Remove Back Cover (4-3) and “Cable Rubber Ring” (3-2) and pull back them along cables
- Remove Power Contacts simply with a small screw driver pushing down retaining contacts springs and pull cables
PSF75 2 Power + 8 Signal Contacts
- Remove Back Cover (5-4) ,“Cable Rubber Ring” (4) and Signal Rubber Ring” (2-3) and pull back them along
cables and wires - To remove Power Contacts same procedure as above point 2
- To remove Signal Contacts it is necessary to extract“Holders” (6) from housings using a special tool
(see “Tooling” section). Insert tool front housing then pull out Holder, eventually using a little plier
to extract Holder and contacts - In case of repair it is necessary to replace Holder and contacts be in touch with ITC for further information